produtos

2
3

TFD04 Split Style Syringe Pump

Pequena descrição:

Faixa de fluxo:

Número máximo de canais: 8

Envie um e-mail para nós

Introdução

Lead Fluid TFD04 laboratory syringe pump, transmission accuracy error<±0.5%, can independently control 1~8 channel operation. Split design, more flexible usage. 7-inch HD color touch screen display and operation, funções poderosas, operação simples, rich operating information. Comunicação RS485, suporta protocolo MODBUS.

Recurso

• Can independently control 1~8 channel operation.
• 7-inch HD color touch screen display and operation, bringing a good user experience.
• Sistema de software LF-Touch-OS, friendly interface, reliable operation.
• Accurate flow control, transmission accuracy error<±0.5%.
• Intelligent flow correction function.
• Four working modes:only infuse, only withdraw, infuse/withdraw, withdraw/infuse.
• With fast filling and emptying function.
• Support start delay and cyclic operation.
• Save five groups of formula parameters.
• Comunicação RS485, Protocolo MODBUS, support the setting of communication parameters, convenient to connect with various control device.
• External control signal controls start, stop, pause, and physical isolation.
• Super anti-interference characteristics, projeto de ampla tensão, adequado para ambientes complexos de fonte de alimentação
• High-strength metal case with protective coating, corrosion-resistant and easy to clean.
• The internal circuit is treated with special protection to prevent dust, moisture and static electricity.

Parâmetro técnico

Canal 1~8 channels,independently control
Tamanho da seringa 0.5μL~60mL(replace the execution unit)
Syringe selection built-in mainstream brand syringe specifications, support customization
Working mode infuse, withdraw ,infuse/withdraw, withdraw/infuse
Precisão error<±0.5%(>30% of pump stroke)
Flow calibration intelligent guide
Mostrar 7 inch 65565 color LCD
Operation method Touch screen
Delay time 0.1~999 s/min/h
Cycles 0~9999
Cycles interval time 0.1~999 s/min/h
Power-down memory Memorize parameters set before power off
Status signal output 5V TTL,1 road indicates running status, 1 road indicates direction status
Control signal input 5~24V Wide voltage, control start, stop and pause
Comunicação RS485,support Modbus protocol
Fonte de energia AC100~240V,50Hz/60Hz
Consumo de energia Controller 40W+30W (each execution unit)
Ambiente temperature5~40℃ ,umidade relativa <80%
Controller dimension 200×142×88mm
Controller weight 2.0kg

 

Execution Unit
ZX01 ZX02 ZX03
Seringa 5μL~1000μL 10μL~60mL 0.5μL~100μL
Faixa de fluxo 0.058nL/min~1,587mL/min 0.184nL/min~83.318mL/min 0.005nL/min~152.456μL/min
Canal 1~8 1~4 1~8
Max stroke of pump 70milímetros 110milímetros 70milímetros
Max rated thrust >2kgf,Adjustable thrust >10kgf,Adjustable thrust >1kgf,Adjustable thrust
Advance per microstep 0.198μm/μstep 0.156μm/μstep 0.1905μm/μstep
Velocidade linear 0.635μm/min~95.25mm/min 1μm/min~150mm/min 0.6096μm/min~91.44mm/min
Execution unit dimension 195×43.5×70mm 266×86×76mm
Execution unit weight 0.85 KG 1.8 KG 0.25 KG

 

Reference Table of Syringe Specifications and Flow Rate

ZX02

Tamanho da seringa Syringe ID (milímetros) Min flow rate (nl/min) Max flow rate (ml/min)
10μl 0.485 0.184 0.027
25μl 0.729 0.417 0.0626
50μl 1.03 0.833 0.125
100μl 1.457 1.667 0.250
250μL 2.304 4.169 0.625
500μL 3.256 8.326 1.248
1mL 4.699 17.342 2.601
5mL 11.989 112.89 16.933
10mL 14.427 163.469 24.520
20mL 19.05 285.027 42.754
30mL 21.59 366.090 54.913
60mL 26.594 555.459 83.318

ZX03

Tamanho da seringa Syringe ID (milímetros) Min flow rate (nl/min) Max flow rate (μl/min)
0.5μL 0.103 0.005 0.761
1μL 0.146 0.01 1.531
2μL 0.206 0.020 3.047
5μL 0.3257 0.051 7.618
10μl 0.485 0.112 16.893
25μl 0.729 0.254 38.166
50μl 1.03 0.507 76.190
100μl 1.457 1.016 152.456

Os parâmetros de fluxo acima são obtidos usando tubo de silicone para transferir água pura sob temperatura e pressão normais, na verdade, usá-lo é afetado por fatores específicos, como pressão, médio etc.. Acima apenas para referência.

Dimensão

Execution Unit Dimension (UN:mm)

Controller Dimension (UN:mm)

Declaração:A explicação final das informações acima pertence ao Lead Fluid.

Leave Your Message