Correo electrónico:[email protected]


Producto

2
3

TFD04 Split Style Syringe Pump

Breve descripción:

Rango de flujo:

Número máximo de canales: 8

Envíenos un correo electrónico

Introducción

Lead Fluid TFD04 laboratory syringe pump, transmission accuracy error<±0.5%, can independently control 1~8 channel operation. Split design, more flexible usage. 7-inch HD color touch screen display and operation, funciones poderosas, operación simple, rich operating information. comunicación RS485, admite protocolo MODBUS.

Característica

• Can independently control 1~8 channel operation.
• 7-inch HD color touch screen display and operation, bringing a good user experience.
• Sistema de software LF-Touch-OS, friendly interface, reliable operation.
• Accurate flow control, transmission accuracy error<±0.5%.
• Intelligent flow correction function.
• Four working modes:only infuse, only withdraw, infuse/withdraw, withdraw/infuse.
• With fast filling and emptying function.
• Support start delay and cyclic operation.
• Save five groups of formula parameters.
• Comunicación RS485, protocolo MODBUS, support the setting of communication parameters, convenient to connect with various control device.
• External control signal controls start, detener, pause, and physical isolation.
• Super anti-interference characteristics, diseño de amplio voltaje, adecuado para entornos complejos de suministro de energía
• High-strength metal case with protective coating, corrosion-resistant and easy to clean.
• The internal circuit is treated with special protection to prevent dust, moisture and static electricity.

Parámetro técnico

Canal 1~8 channels,independently control
Syringe size 0.5μL~60mL(replace the execution unit)
Syringe selection built-in mainstream brand syringe specifications, support customization
Working mode infuse, withdraw ,infuse/withdraw, withdraw/infuse
Exactitud error<±0.5%(>30% of pump stroke)
Flow calibration intelligent guide
Mostrar 7 pulgada 65565 color LCD
Operation method Touch screen
Delay time 0.1~999 s/min/h
Cycles 0~9999
Cycles interval time 0.1~999 s/min/h
Power-down memory Memorize parameters set before power off
Status signal output 5V TTL,1 road indicates running status, 1 road indicates direction status
Control signal input 5~24V Wide voltage, control start, stop and pause
Communication RS485,support Modbus protocol
Fuente de alimentación CA100~240V,50Hz/60Hz
El consumo de energía Controller 40W+30W (each execution unit)
Ambiente temperature5~40℃ ,humedad relativa<80%
Controller dimension 200×142×88mm
Controller weight 2.0kg

 

Execution Unit
ZX01 ZX02 ZX03
Syringe 5μL~1000μL 10μL~60mL 0.5μL~100μL
Rango de flujo 0.058nl/min~1,587 ml/min 0.184nL/min~83.318mL/min 0.005nL/min~152.456μL/min
Canal 1~8 1~4 1~8
Max stroke of pump 70milímetros 110milímetros 70milímetros
Max rated thrust >2kgf,Adjustable thrust >10kgf,Adjustable thrust >1kgf,Adjustable thrust
Advance per microstep 0.198μm/μstep 0.156μm/μstep 0.1905μm/μstep
Linear speed 0.635μm/min~95.25mm/min 1μm/min~150mm/min 0.6096μm/min~91.44mm/min
Execution unit dimension 195×43.5×70mm 266×86×76mm
Execution unit weight 0.85 KG 1.8 KG 0.25 KG

 

Reference Table of Syringe Specifications and Flow Rate

ZX02

Syringe size Syringe ID (milímetros) Min flow rate (nl/min) Max flow rate (ml/min)
10μl 0.485 0.184 0.027
25μl 0.729 0.417 0.0626
50μl 1.03 0.833 0.125
100μl 1.457 1.667 0.250
250µL 2.304 4.169 0.625
500µL 3.256 8.326 1.248
1mililitros 4.699 17.342 2.601
5mililitros 11.989 112.89 16.933
10mililitros 14.427 163.469 24.520
20mililitros 19.05 285.027 42.754
30mililitros 21.59 366.090 54.913
60mililitros 26.594 555.459 83.318

ZX03

Syringe size Syringe ID (milímetros) Min flow rate (nl/min) Max flow rate (μl/min)
0.5µL 0.103 0.005 0.761
1µL 0.146 0.01 1.531
2µL 0.206 0.020 3.047
5µL 0.3257 0.051 7.618
10μl 0.485 0.112 16.893
25μl 0.729 0.254 38.166
50μl 1.03 0.507 76.190
100μl 1.457 1.016 152.456

Los parámetros de flujo anteriores se obtienen utilizando un tubo de silicona para transferir agua pura a temperatura y presión normales., su uso se ve afectado por factores específicos como la presión, medio, etc.. Arriba solo como referencia.

Dimensión

Execution Unit Dimension (UN:mm)

Controller Dimension (UN:mm)

Declaración:El derecho de explicación final de la información anterior pertenece a Lead Fluid..