Produkt

2
3

TYD01-01 Laborspritzenpumpe

Kurzbeschreibung:

Durchflussbereich:

Maximale Anzahl Kanäle:

 

Senden Sie uns eine E-Mail

TYD01-01 Laborspritzenpumpe

● Lead Fluid TYD01-01adopts integrated table model design, 4.3 inch HD LCD touch screen display and operation, can assembly 1 plastic syringe or gas tight syringe, size range of syringe10μL~60mL, flow range 0.184nL/min~ 83.318mL/min.

● Use excellent control system and precision mechanical structure, linear travel accuracy<±0.35%, multiple working modes are available, powerful function,very suitable for high precision micro-transmission of various fluids in scientific research and experiment.

● Drive screw fixation using high strength aviation bearing, compared with traditional copper sleeve bearing, the service life of the screw has been significantly improved, and the accuracy is higher.

● Strong Anti-EMI performance, continuous and stable operation under high voltage electrostatic field.

● RS485 communication, compatibility MODBUS protocol, automation control system can be composed of computer, Plc, single chip computer etc. multiple host computers.

Besonderheit

• Assembly 1 plastic syringes or gas tight syringes.
• Multiple working mode options.
• Color LCD touch screen, convenient operation.
• Support screen lock, key mute operation.
• Button with indicator light,clearly working state.
• support for a variety of syringes, can be customized syringes.
• High accuracy control.
• Syringe protection and traffic jam alarm.
• RS485-Kommunikation,support the MODBUS protocol.
• External signal contol start-stop and direction.
• Wide range power input.
• All-metal anti-static, anti-corrosion spraying process housing.

Technischer Parameter

Woke mode infuse, withdraw, infuse/withdraw, withdraw/infuse, continuous mod
Number of channel 1
Stroke of pump 110mm
Advance per microstep 0.156μm/μstep
Lineare Geschwindigkeit 1μm/min~150mm/min
Linear resolution 1μm/min
Linear travel accuracy error <±0.35%(>30%of pump stroke)
Max rated linear force >16kgf
Thrust regulation 1~100% arbitrary adjustable
Syringe size 10μL~60mL
Syringe selection built-in main manufacturers, the main model syringe to choose, Can use custom syringe, direct input syringe size and diameter
Durchflussbereich Flow calibration0.184nL/min~83.318mL/min
Flow calibration through the calibration procedure to obtain more accurate fluid volume
Display mode 4.3-inch color LCD, with screen display and transfusion volume, residual fluid volume, flow, operation display operation status, direction,syringe specification, Animation display operation status
Operation mode touch screen + common function keys
Power-off memory storing the running parameters automatically
Function pause and stop,the sound tip,the lock parameters,fast forward and retreat quickly,display brightness adjustment
State signal output 1 road start-stop status ,1 road direction status
Control signal input 1 road the falling edge triggers start and 1 road the falling edge triggers stop.
Kommunikationsschnittstelle RS485,MODBUS-Protokoll
Dimension (L×W×H)245×195×140mm
Gewicht 3.2kg
Stromversorgung AC100~240V,50/60Hz
Environment temperature 0~40℃relative humidity<80%

LCD Touch Screen

Reference Table of Syringe Specifications and Flow Rate

Syringe size Syringe ID(mm) Min flow rate (nl/min) Max flow rate (ml/min)

10μL

0.485

0.184

0.027

25μL

0.729

0.417

0.0626

50μL

1.03

0.833

0.125

100μL

1.457

1.667

0.250

250μL

2.304

4.169

0.625

500μL

3.256

8.326

1.248

1ml

4.699

17.342

2.601

5ml

11.989

112.890

16.933

10ml

14.427

163.469

24.520

20ml

19.05

285.027

42.754

30ml

21.59

366.090

54.913

60ml

26.594

555.459

83.318

Die oben genannten Durchflussparameter werden durch die Verwendung eines Silikonschlauchs zur Übertragung von reinem Wasser bei normaler Temperatur und normalem Druck erreicht, Tatsächlich wird es durch bestimmte Faktoren wie Druck beeinflusst, Medium, usw. Oben nur als Referenz.

Dimension (mm)

Stellungnahme:Die endgültige Erklärung der oben genannten Informationen gehört zur Bleifluid.

 

Hinterlassen Sie Ihre Nachricht